CP Faktor X en

Project background

Demineralised water is required for the production of a chemical base material. Drinking water is available for this application.

  CP Faktor X Beitrag

Goal and challange

Deionised water with a residual ion load of < 1 mg/l is produced from drinking water. Due to the use of drinking water, the highest possible recovery must be applied.

Concept and realisation

In order to achieve the desired permeate quality, a multi-stage desalination with a permeate-staged reverse osmosis is provided. This plant was equipped with an OSMO factor X to increase the recovery from approx. 80 % to over 90 %. In addition, the plant was equipped with an OSMO-CIP to enable uncomplicated cleaning of the membrane system..  

Advantage for customer

  • Production of high-quality deionized water quality with low chemical consumption
  • Best possible water utilization through OSMO Factor-X, which saves approx. 75 000 m³ of fresh water per year compared to conventional systems.
  • Reduction of the amount of waste water produced by over 50% compared to conventional reverse osmosis systems
 

Facts and figures

 Commissioning:   2016
  Plant capacitiy:   120 m³/h
 Feed medium:   Trinkwasser

 

 

 

Process:

Icon Umkehrosmose FINAL      
 Reverse osmosis      

 

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.